By complying with the methods required by the tests required, we make the necessary arrangements and carry out the certification processes in the following standards.

 

TS EN 50124-1 / A1 Railway applications - Insulation coordination - chapter 1: Basic requirements - Insulation intervals and surface leakage path lengths for all electrical and electronic equipment

TS EN 50124-1 / A2 Railway applications - Insulation coordination - Part 1: Basic requirements - Insulation intervals and surface leakage path lengths for all electrical and electronic equipment

Electrical safety in low voltage distribution systems - up to 61557 v aa and 1 v - Equipment for testing, measuring or monitoring protective devices - Part 1000: General features

TS EN 61557-2 Electrical safety in low-voltage distribution systems - up to 1000 v aa and 1500 v da - Equipment for testing, measuring or monitoring protective devices - Part 2: Insulation resistance

TS EN 61557-3 Electrical safety in low-voltage distribution systems - up to 1000 v aa and 1500 v da - Equipment for testing, measuring or monitoring protective devices - Part 3: Loop impedance

TS EN 61557-4 Electrical safety in low voltage distribution systems - up to 1000 v aa and 1500 v da - Equipment for testing, measuring or monitoring protective devices - Part 4: Resistance of earth connection and equipotential bonding

TS EN 61557-5 Electrical safety in low voltage distribution systems - up to 1000 v aa and 1500 v da - Equipment for testing, measuring or monitoring protective devices - Part 5: Resistance to earth

TS EN 61557-6 Electrical safety in low-voltage distribution systems - up to 1000 v aa and 1500 v da - Equipment for testing, measuring or monitoring protective devices - Part 6: Efficiency of residual current devices in Tt, tn and it systems

TS EN 61557-7 Electrical safety in low voltage distribution systems - up to 1000 v aa and 1500 v da - Equipment for testing, measuring or monitoring protective devices - Part 7: Phase sequence

TS EN 50124-1 / AC Railway applications - Insulation coordination - Part 1: Basic rules - Insulation intervals and surface leakage path lengths for all electrical and electronic equipment

TS EN 50124-1 / AC: 2007 Railway applications - Insulation coordination - Part 1: Basic rules - Insulation intervals and surface leakage path lengths for all electrical and electronic equipment

TS EN 61557-13 Electrical safety in low-voltage distribution systems - up to 1000 v aa and 1500 v d.a - Testing, measuring or monitoring of protective devices - Part 13: Hand-held or actuated for leakage current measurements in electrical distribution systems current clamps and sensors

TS EN 61557-5 Electrical safety in low voltage distribution systems - up to 1 kv 'aa and 1,5 kv' - Equipment for testing, measuring or monitoring protective devices - Part 5: Resistance to earth

TS EN 61557-1 Electrical safety in low voltage distribution systems - Up to 1 kv aa and 1,5 kv d.a - Equipment for testing, measuring or monitoring protective devices - Part 10: Testing, measuring and monitoring protective devices

TS EN 61557-12 Electrical safety in low voltage distribution systems - up to 1 kv aa and 1,5 kv d.a - Equipment for testing, measuring or monitoring protective devices - Part 10: Performance measurement and monitoring devices

TS EN 61557-15 Electrical safety in low-voltage distribution systems up to 1000 V aa and 1500 V - Equipment for testing, measuring and monitoring protection measures - Part 15: Functional safety rules for insulation monitoring elements in IT systems and locating insulation defect in IT systems Hardware for

TS EN 61936-1 Power plants exceeding 1 kv a.a - Part 1: General requirements

TS EN 61936-1: Power plants exceeding 2010 / A1 1 kv a.a - Part 1: General requirements

tst EN 61936-1 Power plants exceeding 1 kv a.a - Part 1: General requirements

TS EN 61936-1: Power plants exceeding 2011 / tstA1 1 kv a.a - Section 1: General requirements

TS EN 61936-1: Power plants exceeding 2011 / tstAC 1 kv a.a - Section 1: General requirements

TS EN 50124-1 / AC: 2007 Railway applications - Insulation coordination - Part 1: Basic rules - Insulation intervals and surface leakage path lengths for all electrical and electronic equipment

Electrical safety of low voltage distribution systems up to 61557 V aa and 16 V - Equipment for testing, measuring or monitoring protection measures - Part 1000: Equipment for efficiency testing of electrical and / or medical electrical equipment protection measures

TS EN 61557-8 Electrical safety in low voltage distribution systems - up to 1 kv aa and 1,5 kv d.a - Test equipment for testing, measuring or monitoring protective devices - Part 8: Insulation control devices for IT systems

TS EN 61557-8 / AC Electrical safety in low voltage distribution systems - up to 1 kv aa and 1,5 kv d.a - Test equipment for testing, measuring or monitoring protective devices - Part 8: Insulation control devices for IT systems

TS EN 60071-2 Insulation coordination - Part 2: Application guide

TS EN 50124-1 Railway applications - Insulation coordination - Part 1: Basic rules - Insulation intervals and surface leakage paths for all electrical and electronic equipment

TS EN 50124-2 Railway applications - Insulation coordination - Part 2: Overvoltages and related protection

TS EN 50209 Insulation test of rods and coils of high-voltage machines